Technical Specifications - HSC AiP 10
HSC AiP 10S
Parameter
Technical Data Value
Full MPPT Range
130 - 500 V
Max. Input Current
18.5 x 3 A
Max. Short Current
26 x 3 A
No. of MPP Tracker / No. of PV String
3 / 4
Max. Charge / Discharge Power
10 kW
Max. Charge / Discharge Current
240 A
Battery Normal Voltage
51.2 V
Battery Voltage Range
40 - 60 V
Battery Type
Li-ion / Lead-acid etc.
AC Grid & Diesel Gen (Optional)
Max Continuous Current
46 A
Max Continuous Power
10 kVA
Nominal Grid Current
46 / 44 A
Nominal Grid Voltage
190 to 242 @ 220 / 207 to 260 @ 230
Nominal Grid Frequency
50 / 60 Hz
Power Factor
0.999 (Adjustable from 0.8 overexcited to 0.8 underexcited)
Max Continuous Current
46 A
Max Continuous Power
10 kVA
Max Peak Current (10min)
69 / 66 A
Max Peak Power (10min)
15 kVA
Nominal AC Voltage L-N
220 / 230 V
Nominal AC Frequency
50 / 60 Hz
European Efficiency
98.1%
PV Reverse Polarity Protection
Yes
Bat. Reverse Polarity Protection
Yes
Over Current / Voltage Protection
Yes
Anti-Islanding Protection
Yes
AC Short Circuit Protection
Yes
Residual Current Detection
Yes
Ground Fault Monitoring
Yes
Enclosure Protect Level
IP65 / NEMA4X
Dimensions (W x H x D)
785 x 614 x 258 mm
Relative Humidity
0 - 100%
Operating Temperature Range
-25 to 60°C (Derating 45)
Operating Altitude
< 2000 m
Standby Consumption
< 30 W
Communication with RSD
SUNSPEC
Display & Communication Interfaces
LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G
Certification & Approvals
NRS097, G98, EN50549-1, C10/C11, AS4777.2, VDE-AR-N4105, VDE0126, IEC62109-1, IEC62109-2
EMC
EN61000-6-2, EN61000-6-3